Condition survey and assessment
- Measure vibration, bearing temperature, flow rate and actual head, then compare the results with the design performance curve.
- Check for abnormal noise and leakage at the mechanical seal and connecting flanges.
- Review the operating history and identify the root cause when pump performance declines or damage occurs.